Many medical device companies outsource some or all of their software development. Startups may not have a full engineering team, while established manufacturers often bring in specialist partners for mobile apps, cloud platforms or embedded firmware. Outsourcing can speed up development and fill skill gaps, but it also raises a critical question: who is responsible for security?
The short answer is that the manufacturer remains accountable to regulators, no matter who writes the code. This article explains how to structure outsourced medical software projects so that security, documentation and regulatory evidence are built in from the start.
Why Security Is Different for Medical Device Software
Medical device software is not ordinary business software. If a connected device is compromised, the consequences can include incorrect therapy, loss of critical data or disruption to hospital systems. Regulators therefore expect manufacturers to show that security has been considered across the whole product lifecycle, from design to postmarket updates.
In the US, connected “cyber devices” must include specific cybersecurity information in premarket submissions, including a software bill of materials and plans to manage vulnerabilities after launch. Those requirements apply to all software in the device system, whether it was built in-house or by a vendor.
Common Pitfalls When Outsourcing
Outsourced projects tend to run into security trouble in predictable ways:
- Contracts focus on features and deadlines but say little about secure development practices
- Vendors use their usual libraries and tools without tracking components for an SBOM
- Security testing is left until the end, when fixing issues is expensive
- Documentation needed for regulatory submissions is incomplete or missing
- Source code, build environments and signing keys are not handed over cleanly
- Nobody is clearly responsible for patching vulnerabilities after release
Each of these can delay a submission or leave the manufacturer scrambling to reconstruct evidence.
Building Security Into the Vendor Relationship
The best time to address security is before development starts. A few measures make a significant difference.
Set Expectations in the Contract
Specify the secure development practices you expect, the security deliverables required, how vulnerabilities will be reported and fixed, and who owns code, build pipelines and cryptographic keys.
Agree on a Secure Development Framework
Both parties should work to a shared, documented framework covering threat modeling, secure coding standards, code review, dependency management and testing.
Track Every Component
Require the vendor to maintain an accurate list of third-party and open-source components, with versions, so that an SBOM can be produced and kept current.
Plan Independent Testing
Independent security testing provides objective evidence and often finds issues that development teams miss. Schedule it at meaningful points, not only at the end.
Bringing in Security Specialists
Most outsourced development partners are strong at building software but are not experts in medical device regulation. Manufacturers often close that gap by working with a dedicated medical device security firm alongside their development vendor. Specialists such as those at bluegoatcyber.com provide services like threat modeling, penetration testing, SBOM preparation and FDA cybersecurity documentation, giving manufacturers independent evidence that the outsourced code meets regulatory expectations.
This three-way setup, with the manufacturer, development partner and security specialist working together, keeps responsibilities clear and avoids a last-minute rush before submission.
Using Recognized Frameworks
Using a recognized framework gives manufacturers and vendors a common language for secure development. The National Institute of Standards and Technology’s Secure Software Development Framework (SP 800-218) (https://csrc.nist.gov/pubs/sp/800/218/final) sets out a core set of high-level secure development practices that can be integrated into any software development lifecycle, from preparing the organization to protecting software and responding to vulnerabilities. Referencing it in vendor contracts and statements of work makes expectations concrete and auditable.
Handover and Long-Term Maintenance
Medical devices often stay in use for many years, well beyond a typical outsourcing contract. Before a project ends, make sure you have the complete source code, build scripts, documentation, test results, the current SBOM and control of any signing keys. Agree on how future security updates will be handled, whether by the original vendor, a new partner or an internal team.
A Checklist for Manufacturers
- Include secure development and security deliverables in every vendor contract.
- Agree on a shared secure development framework at kickoff.
- Require continuous component tracking for the SBOM.
- Schedule independent security testing at key milestones.
- Keep regulatory documentation up to date throughout the project.
- Secure full handover of code, keys and build environments.
Accountability Stays With the Manufacturer
Outsourcing medical device software can be a smart way to move faster and access specialist skills, but regulators will always hold the manufacturer responsible for security. By setting clear expectations in contracts, adopting a shared secure development framework, tracking every component, testing independently and planning for long-term maintenance, manufacturers can get the benefits of outsourcing without compromising patient safety or regulatory success.
- Outsourcing Medical Device Software Securely - November 28, 2026
- How to Install Playwright in VS Code and Run Your First Test - November 27, 2026
- Top 10 Supply Chain Software Development Companies in 2026 – Best Partners for WMS and TMS Projects - November 27, 2026